This activity means that in this case the measuring device become the subject of the test. So as to able to measure satisfactorily, need to know the performance of our measuring devices. Since this service reveals the failures and errors of the instrument in documented form, helps to handle this issue.

The user will receive a certificate about his measuring device, holding this then will easily be able to decide which measurement task can be done with it, and moreover he must also decide when need to re-calibrate it. Most of our costomers are those, who are operating in certified quality system, because this service is closely integrated into their systems. The certification of the National Accreditation Board shows unambiguously the proper quality of our calibration services.


Measuring tape, measuring rule

Measuring tape, measuring rule

Values measured with standard or reproduced, and measuring range:

  • Measuring tape: 0-50 m
  • Measuring rule: 0-3 m
  • Resolution of the calibration standard: 0.01 mm

Caliper gauge, depth gauge

Caliper gauge, depth gauge

Values measured with standard or reproduced, and measuring range:

  • 0-1000 mm
  • Precision class of the calibration standard: 1

Height gauge

Height gauge

Values measured with standard or reproduced, and measuring range:

  • 0-1000 mm
  • Precision class of the calibration standard: 1

Dial gauge, touch point indicator 3D

Dial gauge, touch point indicator 3D

Values measured with standard or reproduced, and measuring range:

  • Digital, analogue: 0…50 / 0.001 mm
  • Resolution of the calibration standard: 0.0005 mm

External and depth micrometer

External and depth micrometer

Values measured with standard or reproduced, and measuring range:

  • 0…525 mm
  • Precision class of the calibration standard: 0.1

Angle gauge

Angle gauge

Values measured with standard or reproduced, and measuring range:

  • 0 – 360˚

Bubble-level (bricklayers type)

Bubble-level (bricklayers type)

Values measured with standard or reproduced, and measuring range:

  • Bubble-level (bricklayers type): to 1 m frame length
  • Sensitivity of the calibration standard: 0.001 mm/m

Hand-level (engineers type)

Hand-level (engineers type)

Values measured with standard or reproduced, and measuring range:

  • Hand-level (engineers type): 0, 1; 0.02 mm/m
  • Sensitivity of the calibration standard: 0.001 mm/m

Feeler gauge, layer-thickness standards

Feeler gauge, layer-thickness standards

Values measured with standard or reproduced, and measuring range:

  • 0 … 5 mm
  • Resolution of the calibration standard: 0.001 mm

Clamp thickness gauge

Clamp thickness gauge

Values measured with standard or reproduced, and measuring range:

  • 0 … 100 mm
  • Resolution of the calibration standard: 0.01 mm

Ultrasonic thickness gauge

Ultrasonic thickness gauge

Values measured with standard or reproduced, and measuring range:

  • 0 … 100 mm
  • Resolution of the calibration standard: 0.01 mm

Layer-thickness gauge

Layer-thickness gauge

Values measured with standard or reproduced, and measuring range:

  • 0 … 100 mm
  • Resolution of the calibration standard: 0.01 mm